Re: 2 mecs, 3 eds1000 & 442 I need a little help [message #63346 is a reply to message #63341] |
Wed, 18 January 2006 16:43 |
Aaron Allen
Messages: 1988 Registered: May 2008
|
Senior Member |
|
|
Sounds like you don't have an external clock source? If that's the case, no
go bro. Paris has an internal word clock limit of two interfaces (be they
MEC or 442) w/o having to purchase some external clock love. If you actually
got it to boot that way and see everything, you're the only guy I know of. I
sure wouldn't think that would be stable even that being the case.
Did I miss anything?
AA
"Kip Sonnier" <fender36@cox.net> wrote in message news:43ced1bc$1@linux...
>
> 1 Black Mec
> 1 Blue Mec
> 442
> 3 eds1000
>
> Well I finaly got paris to booth without no errors, but its showing
> different
> cards on different Mecs and submixes,
> I want black Mec as Master and Submix A which is connected to card 1
> I want blue Mec as Mec 2 and Submix B which is connected to card 2
> And 442 as 3 interface as Submix C which is conneted to card 3
>
> In the configuration in Paris, i have to set the MasterCard on B to bootup
> without errors. in the Patch Bay it shows the Blue Mec which is hooked up
> to card 2 as Mec A Modules and the Black Mec which is hooked up to Card 1
> as Mec B Modules.
> I do have BNC Cable hooked up for word clock. i also when put in
> UseHouseSync=1
> in the paris.cfg file and it gave me a could inialize paris engine. check
> all cards seperately and they all work good, checked all cables,all good.
> Its works, but i want
> Black mec as Master and Submix 1 with Card A
> Blue Mec as Submix 2 with Card B
> 442 as Submix 3 with Card C
>
> Thanks for any Help
>
|
|
|